Commercial kitchen certificate scope guide

A commercial gas certificate covers only the equipment and checks actually listed

A boiler, plant-room or landlord gas record does not automatically include the catering line. Before booking, define the fuel, supply, every kitchen appliance, ventilation arrangement and evidence needed so the engineer and record match the real job.

Appliance list agreed firstFuel and engineer categories checkedRecord limitations made clear

The direct answer

Four tests decide whether catering appliances are covered

Named equipment

Every appliance must be in scope

The booking and final record should identify each oven, cooker, fryer, grill, chargrill, hob, water boiler or other gas appliance inspected. Equipment left off the list should not be assumed to be covered.

Correct fuel

Natural gas and LPG are separate

Confirm mains natural gas, bulk LPG, cylinders or a mixed arrangement. The engineer's registered competence and the inspection method must match the fuel as well as the appliance.

Relevant work category

Commercial does not mean every appliance

Commercial boiler, pipework or plant competence does not by itself cover commercial catering appliances. Check the engineer's current Gas Safe ID-card categories for the exact work.

Recorded checks

The document must show what was done

A useful record identifies the checks, results, defects, limitations and safety actions. The certificate title cannot expand a visit that covered only part of the installation.

Certificate scope matrix

Similar record names can cover very different gas work

Record or visit Usually addresses Does not automatically include Best booking route
Commercial catering gas-safety record, often called CP42 Fixed kitchen supply, declared cooking appliances, visible pipework, ventilation relationship, extraction, interlocks, flues, safety devices and findings within scope. Boilers, plant rooms, laundry appliances, landlord accommodation or mobile units unless expressly added with the right competence. Declare every fixed-kitchen appliance and whether the fuel is natural gas or LPG.
General commercial gas or plant record Named boilers, water heaters, plant, meters, pipework or other specifically agreed commercial equipment. Cookers, ovens, fryers, grills and the catering ventilation relationship merely because they share a meter or building. Request a separate or combined commercial catering scope with matching categories.
Landlord Gas Safety Record Relevant appliances and flues provided for residential tenants or licensees, with the statutory landlord information and distribution duties. A restaurant, hotel or takeaway kitchen operating as a commercial workspace. Separate residential landlord and commercial catering scopes where both exist.
Mobile catering LPG or CP44-style record Declared mobile unit, cylinders, regulators, hoses, pipework, appliances, isolation, ventilation, movement and findings. A fixed commercial kitchen or equipment that was not present, connected or declared at the inspection. Send the complete vehicle, trailer, horsebox, stall or mobile-bar arrangement.
Service or repair record Maintenance, adjustment, cleaning, parts, tests and condition for the named appliance or fault. A whole-installation gas-safety inspection or a satisfactory certificate after defects remain. Say whether you need service, repair, safety inspection or more than one outcome.

Start with the asset list

Do not book "one commercial gas certificate" for an undefined site

A mixed-use building may contain a restaurant kitchen, bar cellar, boiler room, staff accommodation, outdoor LPG equipment and a mobile catering unit. Those assets can involve different duties, competencies and records even when one business controls the site.

1 · Premises and responsibility

Identify each controlled area

List the trading business, landlord or tenant, kitchen, plant room, accommodation and any mobile unit. Note who owns and maintains each appliance and supply section.

2 · Fuel and supply

Map meters, bulk storage and cylinders

State whether each area uses natural gas or LPG, where isolation is located and whether any outdoor or mobile equipment has a separate cylinder and regulator arrangement.

3 · Appliances

Record every make, model and use

Include cookers, ovens, fryers, grills, chargrills, hobs, boiling tops, water boilers, boilers and specialist equipment. Photos of data plates reduce category mismatches.

4 · Requested evidence

Name the client requirement

Share any council, insurer, event organiser, landlord, managing agent, franchise or contract wording. Upkeepone can then check which record and scope are relevant.

Natural gas and LPG

The appliance may look similar while the fuel route is different

HSE's commercial catering guidance covers gas work involving natural gas and LPG, but the engineer must hold valid competence relevant to the particular equipment and work. Do not assume that an appliance converted between fuels, a cylinder-fed outdoor line or a mobile installation is included in a natural-gas kitchen booking.

Mixed-fuel site?

Send a separate list for each supply. Include meter-fed kitchen equipment, cylinder-fed terrace or event equipment, stored spare cylinders and any mobile unit. The visit may be combined only when the right engineer, access and agreed scope cover every part.

Compare natural gas and LPG or use the commercial LPG certificate route.

Ventilation, extraction and interlocks

The gas appliances cannot be assessed in isolation from the kitchen air system

Adequate make-up air and extraction are essential to remove heat, fumes and combustion products. HSE says the need to interlock ventilation power with the gas supply should be assessed by a competent person. Where extraction serves as a flue for relevant type-B appliances, an appropriate interlocking arrangement is required.

Before the visit

Share the ventilation design and changes

Provide available canopy, fan, make-up-air and interlock information. Declare appliance additions, moves, replacements or increased cooking load since the system was designed.

During the scope check

Separate observation from specialist work

The gas engineer should record relevant findings and limitations. Detailed ventilation design, balancing, electrical interlock work or remedial installation may require additional competent trades and should not be silently assumed.

What useful evidence looks like

A record should help the next duty holder understand the visit

Identification

Who, where, when and which fuel

Trading name, address or unit, inspection date, registered business, engineer identity and the gas type or supply arrangement.

Asset schedule

Every included appliance is recognisable

Appliance type, location and identifying information where available, plus the pipework, isolation, flue, restraint, hose or connection included.

Checks and results

Tests are visible rather than implied

The record should show the agreed checks and relevant results, not merely a certificate label with no usable equipment schedule.

Defects and limits

Outstanding work remains clear

Unsafe findings, advisory items, isolation, inaccessible equipment, excluded areas, remedial action and any return visit should be recorded plainly.

Booking checklist

Send these details before a catering inspection is agreed

Step 1

Describe the site

Postcode, fixed kitchen or mobile unit, business use, trading hours, access, parking, loading, keys, permits and the deadline for evidence.

Step 2

Declare fuel and supply

Natural gas or LPG, meter or cylinders, regulator arrangement, isolation points and whether several supplies or areas must be covered.

Step 3

List all equipment

Every catering appliance plus boilers or other gas equipment, with data-plate photos, installation changes and recent faults where possible.

Step 4

State the required outcome

Safety inspection, CP42-style catering record, mobile LPG or CP44 record, service, repair, installation, commissioning or a combined visit.

Possible gas escape

Do not use an inspection booking as an emergency response

If gas is suspected, avoid flames and do not operate electrical switches. For mains gas in Great Britain call the National Gas Emergency Service on 0800 111 999. For LPG follow the supplier's emergency instructions. Evacuate and call 999 where there is fire, immediate danger or any doubt.

Service areas

Regular commercial catering enquiries across London, Essex and Kent

Regular work covers London, Essex and Kent. Enquiries in Hertfordshire, Surrey, Buckinghamshire, Berkshire and Sussex can also be considered when the right trade is available. Other UK areas are considered by request, subject to the appliance list, engineer categories, travel and appointment requirements.

Choose the related route

Match the page to the equipment and evidence you need

Fixed commercial kitchen

Commercial catering gas certificate

Use this for restaurants, pubs, cafés, hotels, schools, takeaways and production kitchens with declared natural-gas or LPG catering equipment.

Open the fixed-kitchen route

Commercial plant or mixed site

Commercial gas certificate

Use this when boilers, water heaters, plant rooms or other commercial appliances need a defined inspection alongside or separately from the kitchen.

Open the commercial gas route

Mobile LPG unit

Food truck, trailer or mobile bar

Use the mobile route for cylinders, regulators, hoses, movement, storage, ventilation and every appliance in a declared mobile setup.

Open the mobile LPG route

Legal duties and frequency

Commercial catering gas law guide

Use the legal guide for maintenance duties, inspection frequency, competent work, CP42 and CP44 record names, ventilation and interlocks.

Read the catering gas-law guide

Catering certificate scope questions

Commercial gas certificate and catering FAQs

Does a commercial gas safety certificate automatically cover catering appliances?
No. A record covers only the premises, gas supply, appliances and checks included in the agreed scope. A boiler, plant-room or general commercial-gas record does not automatically include cookers, ovens, fryers, grills or other catering appliances. Check that every item is declared, inspected and listed on the catering record.
What should a catering gas-safety record identify?
It should clearly identify the business or premises, fuel, gas supply, every appliance within scope, relevant pipework and isolation, checks completed, results, defects, safety actions, limitations, date, registered business and engineer. Ventilation, extraction, flues, interlocks and appliance restraints should be recorded where they form part of the installation and agreed work.
Can an engineer qualified for commercial boilers inspect catering equipment?
Not on boiler competence alone. Gas Safe work categories are specific. The engineer's current ID card must cover the fuel, commercial catering appliances and exact work involved. A site containing boilers and kitchen appliances may need one engineer with all relevant categories or separately scoped visits.
Is CP42 the correct certificate for a fixed commercial kitchen?
CP42 is a common industry name for a commercial catering gas-safety record for a fixed kitchen. The name does not define the work by itself. Before booking, confirm the premises, fuel, appliance list, supply arrangement, ventilation or interlock questions and the evidence requested by the council, insurer, landlord or client.
Can the same catering record cover natural gas and LPG?
Only where both fuel systems are declared, the engineer holds the relevant competence and the agreed inspection covers them. Natural-gas competence does not automatically include LPG. If a premises has mains-gas kitchen appliances plus cylinder-fed outdoor or mobile equipment, describe both arrangements before attendance.
Does a fixed-kitchen certificate cover a food truck or catering trailer?
Not automatically. A mobile unit has a different installation and operating environment, including cylinders, regulators, hoses, movement, storage, ventilation and isolation. Food trucks, trailers, converted horseboxes and mobile bars should follow a mobile-catering LPG or CP44-style route covering the complete declared unit.
How often should commercial catering gas equipment be inspected?
HSE says intervals can vary with the equipment and its use and should follow manufacturer recommendations, with annual inspection a reasonable general minimum. Condition, intensive use, relocation, alteration, a defect, an insurer or event requirement may justify earlier inspection or maintenance.
Does the inspection include kitchen ventilation and the gas interlock?
The engineer must consider the gas appliances in relation to the ventilation and extraction arrangements, but the exact tests and any specialist ventilation work must be agreed. HSE says the need for an interlock should be assessed by a competent person, and extraction serving as a flue for relevant type-B appliances requires an appropriate interlocking arrangement.
Who should arrange the catering gas inspection in leased premises?
The operator, employer, landlord, tenant, building manager and maintenance provider may control different parts of the premises or installation. Check the lease and contracts, identify who owns each appliance and supply section, and agree access and maintenance responsibilities. A certificate does not transfer every duty from one party to another.
What information should I send before booking?
Send the postcode, premises or mobile-unit type, natural gas or LPG, meter or cylinder arrangement, every appliance and model where available, ventilation and interlock details, access restrictions, trading deadline, recent defects and the exact record requested. Photos of the appliance data plates and overall kitchen or unit can help match the correct engineer categories.

Need the kitchen included?

Send the complete asset list before choosing the certificate name

Upkeepone can check the premises, fuel, catering appliances, other commercial plant, ventilation questions, engineer categories and requested evidence before an appointment is agreed. Attendance, a satisfactory result or one combined record cannot be promised until the scope and findings are known.

Possible gas escapes must follow the emergency route above.