Commercial and workplace bulk LPG installations

Contents hide

Know what the supplier maintains—and what your site must keep safe

A supplier-owned tank does not remove the site operator's duties around access, ventilation, security, vehicle movements, changing surroundings and emergency planning. Confirm the boundary before requesting an inspection or certificate.

Supplier boundary checkedSite conditions recordedWork scope defined first

The direct answer

Start with the supply contract, then inspect the conditions your business controls

HSE says that in the vast majority of cases the LPG supplier owns the tank and generally looks after the tank and its fittings. The site operator nevertheless controls important risks around the installation. Put both sides in writing instead of treating "supplier-owned" as "nothing for us to do".

1. Confirm ownership

Read the contract and records

Identify the tank owner, supplier maintenance scope, fittings covered, emergency number, examinations and any written transfer of pressure-system responsibilities.

2. Record site controls

Look beyond the vessel

Map buildings, boundaries, drains, vegetation, stored materials, ignition sources, people, vehicles, parking, delivery access, security and impact protection.

3. Define the enquiry

Name the output required

State whether you need supplier attendance, gas work, a site review, service-pipework assessment, remedial quotation, risk input or another written record.

This is a preparation and booking guide, not a tank design, separation-distance calculation, hazardous-area classification, written scheme of examination or certificate of compliance.

Six site-user checkpoints

Keep the installation's surroundings consistent with the safe design

Siting and later changes

Do not let the site grow towards the tank

New walls, sheds, fences, electrical equipment, trees, shrubs, work areas or stored materials can alter a once-acceptable arrangement. Record proposed changes before work begins and ask the supplier or competent specialist to assess them.

Ventilation and housekeeping

Prevent clutter and overgrowth

Keep the area open to natural air movement and free from rubbish, combustible material and vegetation that can reduce ventilation or add fire load. Include the tank compound in routine site checks.

Drains and low points

Recognise heavier-than-air vapour

Note drains, gullies, pits, cellars and other low points around the installation. HSE warns that LPG may collect in an untrapped drain or gully; do not decide acceptability without site-specific assessment.

Tanker access

Keep the delivery route usable

Maintain the agreed flat tanker parking area and access route. Before a delivery, remove obstructions and parked vehicles, manage gates and people, and tell the supplier about changes to the site or delivery conditions.

Security and ignition control

Keep unauthorised people away

Maintain required fencing, locked gates or valve covers and clear signs. Manage smoking, electrical equipment, parking, fires and other ignition sources near the tank in accordance with the actual site arrangements.

Vehicle impact

Use protection matched to traffic

Where vehicles may reach the tank or associated pipework, assess physical barriers or bollards for the actual routes and vehicle types. Fencing, paint or road markings alone may not stop an impact.

Tank, pipework and appliances are not one ownership line

Trace responsibility from the tank to the point of use

Ask for the boundary in writing

The supplier may own and maintain the storage tank while the landlord or premises owner owns the service pipework carrying LPG vapour towards the building. Downstream installation pipework, regulators, controls and appliances may sit within other maintenance, gas-work and workplace duties.

Record who owns each section, where the handover points are, what pressure is used, who inspects it, who can isolate it and which emergency number applies. Link this guide to the existing tank-to-factory pipework guide rather than combining two different responsibilities into one certificate.

Delivery-day control

Make safe tanker access a repeatable site process

Before delivery

Check the agreed route and parking area

Confirm gates, height and width restrictions, road condition, turning area, overhead hazards, temporary works, parked vehicles, stored materials and any changed site layout. Tell the supplier rather than asking a driver to improvise.

During transfer

Control people and site traffic

Keep employees, visitors, customers and unrelated vehicles away from the tank and tanker. Follow the supplier's delivery procedure and the site's ignition-control and emergency arrangements.

After a change

Review access before the next delivery

New gates, barriers, charging points, skips, planting, parking bays, drainage, construction work and revised vehicle routes can affect access or risk. Record the change and obtain the appropriate assessment.

After an incident or near miss

Stop and escalate the concern

Damage, a struck barrier, unauthorised entry, blocked emergency access, abnormal smell or unsafe delivery condition should enter the defect and emergency process. Do not wait for the next routine certificate.

Records that make the boundary usable

Keep evidence that joins supplier work to day-to-day site control

Ownership and supply

Contract, owner and emergency contact

Keep the current supply agreement, tank owner, supplier contact, displayed emergency number, tank identification, capacity, fittings and written allocation of maintenance or examination responsibilities.

Inspection and maintenance

Scheme, visits, actions and completion

Retain relevant written scheme and competent-person examination records, supplier service reports, gas-work records, defects, recommendations, due dates and evidence that remedial actions were closed.

Site-user checks

Surroundings, security and access

Record routine checks of housekeeping, vegetation, signs, gates, locks, valve cover, physical protection, parking, drains, nearby activities, delivery access and visible damage without opening or disturbing equipment.

Change and emergency control

Who decides and who responds?

Keep change approvals, risk reviews, emergency plan, evacuation arrangements, staff instruction, drill or incident records and the people authorised to contact the supplier, stop work and prevent reuse.

Leak, damage or fire

Use the supplier's emergency route—not an ordinary certificate enquiry

The supplier's emergency number should be displayed on the tank. Keep people away, avoid ignition sources and follow the site emergency plan. If there is fire, an uncontrolled release, immediate danger or doubt, evacuate and call 999.

Only operate isolation that the emergency plan assigns to trained people and only where it is safe to do so. Do not approach the tank, touch unfamiliar valves, move a vehicle or restore use merely because a smell appears to have stopped. Upkeepone's normal enquiry lines are not an emergency reporting service.

Prepare a usable enquiry

Send the supplier boundary, site layout and required output first

"Check our LPG tank" does not reveal whether the issue belongs to the supplier, tank owner, service-pipework owner, gas installation, appliance, landlord or workplace risk system. These details help identify the route before any attendance is agreed.

Match the provider to the real task

Tank examination, site risk and gas work can need different competence

The tank supplier or pressure-system competent person may cover the vessel and specified fittings. A suitably competent specialist may be needed for site design, impact protection, DSEAR or process risks. Where the Gas Safety (Installation and Use) Regulations apply, gas work must use a Gas Safe registered business and an engineer whose current categories cover the exact LPG work, appliance and premises.

Some factories, agricultural premises and industrial processes sit outside parts of the domestic-style gas regulations and can require a different competent-person route. Ask the proposed provider to state its precise scope, limitations, competence evidence and written output.

Business LPG enquiries

Send the postcode before attendance is assumed

Bulk-tank enquiries are handled regularly in London, Essex and Kent. Hertfordshire, Surrey, Buckinghamshire, Berkshire and Sussex can be considered when a suitable LPG trade is available and the requested work sits outside any supplier-owned tank responsibility. Other UK locations are considered by request after the supplier and ownership boundary, vessel arrangement, delivery access, downstream installation, site risks and required written output are clear. Upkeepone's enquiry review does not replace the LPG supplier's tank examination, maintenance or site instructions.

Check current feedback before sending the site information

Read Upkeepone's live Google results in their original context, then send the postcode, business activity, supplier and ownership documents, tank and pipework information, site photographs, delivery arrangements, available records, known concerns and the exact inspection, report or remedial-work output required. Upkeepone can review the enquiry and check the relevant route and current availability.

Ownership, site control and booking questions

Bulk LPG tank site-safety FAQs

Who is responsible for a bulk LPG storage tank at a business?
The LPG supplier owns the tank in many installations and will commonly look after the tank and its fittings, but the contract and written allocation must be checked. The person operating the site still has responsibilities for conditions around the tank, tanker access, security, impact protection, emergency arrangements and activities that could affect the installation.
Does the LPG supplier look after everything around the tank?
Do not assume so. Supplier responsibilities can cover the tank and fittings, while the site operator controls the surrounding land, access route, parking, vegetation, waste, nearby work, visitors, vehicles, security and emergency plan. Service pipework from the tank towards the building is also often owned by the premises owner rather than the supplier.
Can Upkeepone issue a certificate for a supplier-owned LPG tank?
Upkeepone can review the enquiry and check the appropriate inspection or gas-work route, but a general gas-safety certificate does not replace the tank owner's statutory examination, supplier maintenance or a site-specific risk assessment. Send the supplier, ownership documents, tank details, premises use, photographs, records and exact written output required before attendance is assumed.
What should be kept clear around a bulk LPG tank?
The actual requirements depend on the installation, but the tank area should not be allowed to collect rubbish, combustible material or overgrowth that reduces ventilation. Site changes, sheds, fences, electrical equipment, ignition sources, drains, gullies, parking and stored materials must be reviewed against the supplier's instructions and current applicable guidance.
Why do drains and gullies matter near an LPG tank?
LPG vapour is heavier than air and can collect in low points. HSE warns against drains or gullies near the tank unless an appropriate water trap prevents gas entering them. Do not alter drainage or decide that an existing drain is acceptable from this guide; ask the supplier or a suitably competent person to assess the real site.
What does safe LPG tanker access involve?
HSE describes a dedicated flat parking area that is clear on delivery day, with people kept away from the tank and tanker during transfer. The supplier controls the delivery operation and trained driver procedures, while the site operator must manage gates, obstructions, parked vehicles, changing traffic routes, staff and visitors on the premises.
Are signs and a fence enough to protect an LPG tank from vehicles?
Not necessarily. HSE states that where motor traffic cannot be avoided, physical impact protection such as crash barriers or bollards may be required; a security fence or road markings alone are unlikely to provide that protection. The protection must be assessed for the actual vehicle movements and installation rather than copied from a generic picture.
What records should a business keep for a bulk LPG installation?
Keep the supply contract and ownership boundary, tank and service-pipework information, supplier visits, written scheme or examination records where applicable, maintenance and defect records, risk assessments, site-change reviews, delivery arrangements, emergency contacts, staff instructions and evidence that required actions were completed.
When should the tank area be reviewed again?
Review it whenever the site, traffic, boundaries, buildings, drainage, electrical equipment, vegetation, work activity, supplier, fuel demand or emergency arrangements change, and at the intervals set by the risk assessment, supplier and applicable inspection regime. Routine user checks do not replace competent examinations, maintenance or gas work.
What should we do if we smell LPG or see damage near the tank?
Treat it as an emergency, not a normal inspection enquiry. Keep people away, avoid ignition sources and electrical switches, and follow the supplier's displayed emergency instructions. If there is fire, an uncontrolled release, immediate danger or doubt, evacuate and call 999. Do not operate unfamiliar valves, move a vehicle or restore use unless the emergency plan and competent advice say it is safe.

Need the enquiry assessed?

Send the ownership boundary, site conditions, records and required output

Upkeepone can review the information supplied and check whether the requested LPG scope can be routed to an appropriate trade. An enquiry does not confirm availability, compliance, price or that one attendance can cover the supplier's tank, pressure-system examination, service pipework, gas appliances and workplace risk duties.

Suspected LPG leaks, fire or tank damage must follow the supplier or emergency route above.